IOCARE

12 Lead 12 Channel ECG Machine

$2,265.00 USD $1,299.00 USD Save 43%
Shipping calculated at checkout.

12-Lead 12-Channel ECG Machine | Accurate Cardiac Diagnosis

Shipping & Returns

Row content

Compatibility

Row content

12-channel ekg machine with interpretation

Assist you in making a fast and accurate diagnosis

$1,299.00
$2,265.00

Subscribe to get a 10% off promo code(code will be sent to your email)

! Rx only,  shall be used by qualified health professionals in the medical units

details >
iE12A-ekg-machine-kv

features

Greater mobility

Greater mobility

Weigh only about 3.4kg, easy to carry with an integrated handle

FDA and CE cleared

FDA and CE cleared

FDA and CE cleared, safety, efficacy, and quality are assured

Easy data management

Easy data management

Multiple connectivity and export options to facilitate seamless data access, transfer, and storage.

A fast and accurate diagnosis

A fast and accurate diagnosis

CardioPro™ ECG analysis, proved by the official CSE database, demonstrates high accuracy and reliability in measurement and interpretation.

Intuitive touchscreen

Intuitive touchscreen

1280*800, 9-inch TFT touchscreen with a backlight, 15° tilt angle facilitates viewing

VCG analysis

VCG analysis

VCG accurately records every moment of vector value, direction and process of changing and expands diagnostic capabilities.

Rechargeable battery

Rechargeable battery

4400mAh built-in rechargeable lithium battery for more than 3 hours of continuous work

ECG acquisition and printing

ECG acquisition and printing

Simultaneously records and prints 12-lead resting ECGs featured with a 10 seconds duration.

Smart, Secure, Simple, and Efficient

iE12A ekg machine, simple, secure and efficient

Simple and efficient

  • Effortless capture of 10-second ECGs 
  • On-screen preview of 12-lead waveforms and ECG results facilitates  review and diagnosis
  • Various connectivity and export options for seamless data access, transfer, and storage
  • Alphanumeric keyboard for convenient input and visibility
  • Simplified workflow with one-touch operation
  • User-friendly interface boosts productivity
  • The 9" color touchscreen display enables easy patient data entry

Smart Auto-ECG algorithm

CardioPro™ ECG analysis provides proven software interpretation to support medical professionals and deliver prompt diagnoses for ECG tests. The interpreted report serves as a secondary diagnostic opinion for healthcare professionals.

Inherent system security

Encryption of patient data, authentication via username/password, and secure network connections contribute to ensuring data integrity.

Streamlined barcode workflow

barcode-scanner-800.jpg__PID:f7fac2e7-1772-42ae-9138-8e92c86a128a

Barcode scanner to quickly input patient ID

on-screen-guide-800.jpg__PID:fac2e717-72f2-4ed1-b88e-92c86a128aa4

On-screen guide to check for loose leads

preview-the-report-before-printing.jpg__PID:c2e71772-f2ae-4138-8e92-c86a128aa4a0

Preview the report before printing

Data management solution

data-management-solution.jpg

Storage

Internal Memory, USB, Flash Drive, and SD card internal memory supports more than 3000 ECGs based on 10s;

Connectivity

Multiple ports for data access, transfer, and storage, SD card slot, USB port, LAN port, VGA port;

Export

Export from USB flash disk, Export from SD Card;

ECG File Type

ECG, XML, JPEG, DICOM, PDF;

Upload

Transfer data to ECG management software on a PC by LAN or WIFI(optional) ;

Transfer Protocol

TCP, FTP, and HL7;

Portable, lightweight design

Weigh only about 3.4kg(75.lbs), the perfect size for a professional 12-lead ECG machine.

iE12A dimension data

The Carry handle allows greater mobility, a perfect fit for an EM physician to carry on a daily basis.

Carry handle allows greater mobility

Reliable and accurate interpretation

The CardioPro™  ECG core analysis system offers a complete set of trusted tools rigorously validated against authoritative ECG database-CSE/AHA/ MIT across diverse patient populations. Clinical decision support is made simple.

Analysis-for-adult-and-pediatrics

Analysis of adult and pediatrics

0.01 Hz for high-pass filter, more sensitive in detecting weaker ECG signal, enhancing undistorted ST segment measurement and analysis;

Exclusive analysis module for pediatrics with 250Hz low-pass filer, compliant with the latest standard of AHA/ACC/HRS 2007;

Detailed Measurement Data for Clinical Reference

Automated reporting sequence saves time

iE12A EKG machine combines features created to deliver optimal ECG quality and speed, even in the most challenging situations.

In Standard 12 Leads and Cabrera lead modes, Report (1) includes simple measurement data, Minnesota code, beat waveforms, analysis results, and rhythm waveforms.

ECG recording2

There are six normal record modes, three advanced recording modes of your choice, and a 'Mode' shortcut button for quick operation. Normal modes include economic Recording Mode, Automatic Recording Mode, Manual Recording Mode, Cycle Recording Mode, Trigger Mode, and Upload Mode; Advanced Recording Mode includes Rhythm Mode, Analysis Report Mode, and Freeze Mode.

Rhythm Mode

HRV waveform acquisition

In the rhythm interface, tap [Rhythm Mode], and the system will begin HRV waveform acquisition as shown left (the fixed acquisition time is 300 seconds, displayed in the interface).

HRV-waveform-review.jpg

Analysis Report

in Standard 12 Leads and Cabrera lead modes

The report is displayed on the right and includes a simple measurement area, Minnesota code, beat waveforms display, and analysis result, and you can change the analysis result in this area.

analysis report in Standard 12 Leads and Cabrera lead modes

Analysis Report

in Nehb lead mode

The report is displayed on the right, and includes simple measurement area, and lead waveforms area.

analysis-report(1)-in-Nehb-mode

VCG analysis expands diagnostic capabilities

Besides limb leads, there are X lead, Y lead, and Z lead in VCG. VCG is also a cardiogram for observing and recording heart conditions. It can accurately record every moment of vector value, direction, and change process. It can be used to diagnose myocardial infarction, bundle branch conductive and branch conduction blocks, and atrial and ventricular hypertrophy, especially right ventricular hypertrophy etc.

VCG-analysis-report

Introduction and application video

Seamless data transfer with HIS

The ECG machine can communicate with HIS via the HL7 interface protocol. HIS is short for Hospital Information System. HIS can also widely refer to information platforms or statistic centers interacting with hospitals and HL7 servers through HL7 protocol.

iE12A-ekg-machine-Seamless-data-transfer-with-HIS.jpg__PID:89f99ae8-4475-48cb-88d8-30a353169f1e

Menu Setting Display

search-interface
configure-menu

Other features

Simultaneous 12-lead acquisition

Simultaneous 12-lead acquisition

Multiple Connectivity

Multiple Connectivity

Included Accessories

iE12A ekg machine patient cable

patient cable

iE12A-ekg-machine-power-adapter-and-cable

power adapter and power cable (US or EU Standard)

equipotential-cable.jpg

equipotential cable

Z-fold-Thermal-Recording-Paper.jpg

Z-fold Thermal Recording Paper (160 Pieces, 112mm × 140mm)

limb-electrode.jpg

limb electrode X4

chest-electrode.jpg

chest electrode X6

disposable-electrodes.jpg

disposable electrodes X10(optional)

electrode-adapter.jpg

electrode adapterX10(optional)

Frequently asked questions

All standard orders will be shipped within 1 to 2 business days after confirmation by our team upon receiving your order. If your order contains an item scheduled for later shipment, we will dispatch the entire order once the specified item is available.

Have any other questions?

 Feel free to leave your questions to us. We will reply you within 24 hours!

You may also like

Fast Shipping

Fast delivery from the local warehouse

100% Money Back

Free returns within the first 30 days after receiving

Secure Checkout

Payment from the most popular & secure payment methods

Customer Service

Reach out to our support team via email or live chat anytime